Adhesivity Binder – Aggregates | VIALIT Plates

Principle

Determination of the binder-aggregate adhesivity by measurement of Vialit cohesion.
Determination of the binder-aggregate adhesiveness and the influence of adhesiveness dopes or interface dopes on the characteristics of this adhesiveness. This European Standard defines the methods for determining:

  • The overall adhesiveness of the binder to the aggregate surface
  • The active adhesiveness of the binder on gravel
  • The improvement of the overall adhesiveness and the active adhesiveness by the addition of a dope of adhesiveness is integrated in the mass of the binder or at the binding-gravel interface
  • The wettability temperature of the granulate by the binder
  • The variation of adhesiveness below the brittle limit temperature.

This test method is suitable for all hydrocarbon binders used for surface coatings, fluxed or fluidized bitumens, based on pure or polymer-modified bitumens, or pure or polymer-modified bitumen emulsions and all types of aggregates. used for surface coatings of the following granulometry: series 1: 2 / 5mm, 5 / 8mm, 8/11 mm and 11 / 16mm; Series 2: 2 / 6mm, 4 / 6mm, 6 / 10mm and 10 / 14mm.

Standard

EN 12272-3

Products

Essai à la plaque VIALIT

Complete Set - Vialit plate shock

  • Painted metal base with two vertical rods and angles to support the test plates
  • A full vertical tube ball holder with drop device
  • 500 g steel ball
  • Three test plates
  • A manual compaction roller

F025.150.0970

Accesories

Plaque VIALIT

Pack of 3 plates VIALIT

  • Plates 200 x 200 mm

F025.150.0972